Series Athena
- PVDF Pump head, suitable for chemical used in the Industrial, Waste Water Treatment and Portable Water applications
- Ceramic ball; full chemical compatibility
- PTFE Diaphragm unique life expectancy and compatibility with most chemicals
- Steady dosing stabilized multi power supply 100÷240 Vac 50/60 Hz with reduced consumption
- Quick connections
- Manual priming valve
- IP65 Protection
|
|
Series Hydra
- Electromagnetic dosing pump
- PVC Pump head
- Ceramic ball, full chemical compatibility
- PTFE Diaphragm unique life expectancy and compatibility with most chemicals
- Flow rate manual adjustment 0÷100%
- Manual priming valve
- Wall mounting with fixing bracket (included)
|
|
Series Olimpia
- Electromagnetic dosing pump
- Analogic with constant flow
- PVC Pump head: suitable for chemical use in the industrial, waste water treatment and portable water applications
- Fireproff and anti-acid polypropylene box
- Flow rate manually adjustable 0÷100%
- Manual priming valve
- Power supply and level probe inlet with quick connection
- Working state LED
- IP65 Protection degree
|
|
Series Nike
- Fireproof and anti-acid polypopylene box
- On/Off switch completely protected
- IP65 protection
- Variable speed 10÷100%
- High resolution trimmer for speed regulation and power supply/working LED
- Dimensions 112x90x90 mm
NIKE.M PRO Specifically designed for swimming pool maintenance and dosing of flocculent, anti-algae, air conditioning and essences.
NIKE.M TEMP Spa swimming pool, shower and essences treatment Temporised dosing and batch function (1 min)
|
|
Series System
- Peristaltic products
- Dosing speed regulation via software
- Tank level control
- On/off switch-priming
- 16x2 Display (blue/white)
- Tension input 240 Vac, electrical signal from circulating pumps
- Remote alarm through relays
- Setting of the parameters via menu
|
|
Series Taurus
- Electromechanic dosing pumps
- These pumps are plunger piston metering pumps featuring a spring return stroke in an alluminium housing with oil bath
- Each pump is equipped with manual flow adjustment and can be equipped with an electric actuator which accepts a 4÷20 mA or inventer.
TP/TM.INV
piston/diaphragm dosing pumps with inverter
- SS316 and PVC (TAP), SS316 and PP (TAM) pump head
- max. dosing temperature 90°C (SS), 40°C (PP)
- as standard the pump can be regulated manually, but it can also be coupled to a remote signal, through an electrical servo-control with 4÷20 mA signal
Motor
Asynchronous three-phase motor, IP54 protection, axial servo-venting ICO6. Inverter module pre-installed, ALTAIR-M037 motor, "/B" version, 1 analogic input, 4÷20 mA, 4 digital inputs, 1 serial RS485 input for programming and calibration.
Accessories
Pressure safety valves: are installed to prevent dangerous situations in case of unexpected overpressure that can damage the pump and the pipes. Metering pumps can reach high pressures in one stroke, therefore they should be protected by possible clogging of the pipe caused, for instance, by accidental clousure of valve. Hydraulic sandwich diaphragm pumps are protected with a limating pressure valve buil-in in the hydraulic circuit, the pitting should be protected by in-line pressure safety valve. On request PSV may be supplied with PED certificate.
Back pressure valves: to allow the correct operation of a pump and to prevent the flow-through (siphoning) of the process liquid, the discharge pressure should be greater than the suction pressure; when this condition is not respected then a backpressure valve can be the solution.
Pulsation bag: the reciprocating movement of the piston generates pulsations: during each stroke the liquid contained in the suction and discharge lines is accelerated from zero to the maximum speed and then decelerated to zero again. Pulsation dampers are the suggested accesssories to reduce high and unwanted dangerous pressure fluctuations or to obtain a linearity of the flow.
|
|
Series Nexus.1000
- Measuring and control instruments
- Output 4÷20 mA ideal solution for connecting to a logger or data acquisition system
- Selectable measurment scales using the programming menu, it is possible to select the available measurement scale to ensure operating versatility with a single instrument
- Instrument recognises the buffer solution (pH and Redox) and completes the calibration suspending the dosage (HOLD) and showing the electrodes efficieny in %
- Multilingual menu, password protection for setting menu, quality indication of measuring probes.
Technical features
Range pH - 0÷14,00 (accuracy 1%) Rx - ±1000 mV (accuracy 1%) CD - 10÷20,000 µS (accuracy 1%) sonda probe K10 - 10÷2,000 µS (accuracy 1%) sonda probe K5 - 20÷4,000 µS (accuracy 1%) sonda probe K1 - 100÷20.000 µS (accuracy 1%) Temperature 0÷100°C with PT100 (accuracy 1%) Current output 0/4÷20 20÷4/0 mA (±2%) Set point 2 independent through 10A 250 V dry content relay (resistance load)
|
|
Series Nexus.2000
Technical features
NX2000 series range pH - 0÷14,00 (accuracy 1%) Rx - ± 1000 mV (accuracy 1%) CD - 10÷20.00 µS (accuracy 1%) probe K10 - 10÷2,000 µS (accuracy 1%) probe K5 - 20÷4,000 µS (accuracy 1%) probe K1 - 100÷20,000 µS (accuracy 1%) Flow - 0÷9.999.999 (input signal 0,5÷1.500 Hz) Batch function - calculation of an established volume NX2500 series range PR - 0÷14,00 / ± 1500 mV pH/CD - 0÷14,00 / 0÷20 mS ph/CL - 0÷14,00 / 0÷200 ppm pH/Flow - 0÷14,00 / 0÷9.999.999 l/h CD/Flow - 0÷20 mS / 0÷9.999.999 l/h Temperature 0÷100°C with PT100 (accuracy 1%) Current output 0/4÷20 20÷4/0 mA (±2%) galvanic separation Power supply 100÷240 VAC 50/60 Hz Set point 2 independent through 10A 250V dry contact relay (resistance load)
|
|