Kobold manjsi

 

Variable Area Flowmeter-Class Cone URB

Measuring range:
10-100 ... 100-1000 L/h water
0,32-3,2 ... 3,2-32 Nm³/h air
Connection: G ½...1¼
Material: st. st.
Max. pressure: 6 bar
Max. temperature: 65 °C
Accuracy: ±2,5...4% f.s.

Variable Area Flowmeter-Class Cone UVR/UTR

Measuring range: 10-100 ... 200-2000 L/h water
0,1-1 ...5-50 Nm³/h air
Connection: G 3/8, G ½ female
Material: POM-C, st. st.
Max. pressure: 6 bar
Max. temperature: 100 °C
Accuracy: ±2,5...4% f.s.

Variable Area Flowmeter-Class Cone-Loose Flange URL

Measuring range:
1-10 L/h ... 250-2500 L/h water
0,02-0,2 ... 10-100 Nm³/h air
Connection: flange DN 15...40
Material: PVC, PVDF
Max. pressure: 6 bar
Max. temperature: 100 °C
Accuracy: ±2,5...4% f.s

 Variable Area Flowmeter/-switch V31

Measuring -/switching range: 1,1 - 11 NL/h ... 1.000 - 10.000 L/h water
36 - 360 L/h ... 18 - 180 Nm³/h air
Connection: G ½... G2 fem, hose connector, glue-in conn.,
flange: DN 15..DN50, ANSI 1/2 ..2
Material: glass inside protection tube
Max. pressure: 15 bar Max. temperature: 0.. 80 °C
Accuracy class: 1,6/2,5
Option: contact

 Variable Area Flowmeter-Class Cone-Fixed Flange URK

Measuring range:
1-10 L/h ... 15000-50000 L/hwater
0,02-0,2 ... 50-500 Nm³/h air
Connection: flange DN 15...80, ANSI ½ ...3
Material: cast iron.
Max. pressure: 20 bar
Max. temperature: 100 °C
Accuracy: ±2,5...4% f.s.

Manifold Valves for multiple installation for liquids USR

Measuring range:
0,04 - 0,4 ... 1 - 10 l/min water
pmax: 16 bar
tmax: + 100 ° C (medium) / + 60 ° C (ambient)
Connection inlet:
G 1 or 1 "NPT (with adapter)
Connection outlet:
female thread G 1/4, G 3/8, 1 "NPT, 3/8" NPT, hose Ø10, Ø13 or Ø15 mm

 Variable Area Flowmeter-Class Cone for Compressors UTS

Measuring range: 10-100 L/h… 0,3 - 3 Nm³/h air
Connection: M18x1,5
Material: brass, st. st.
Max. pressure: 3 bar
Max. temperature: 55 °C
Accuracy: ±2,5...4% f.s.

 Variable Area Flowmeter DSV-1

Measuring -/switching range: 0,25 - 1,25 L/min ...
10 - 130 l /min water
Connection:G ¼ - G 1 ¼ , ¼ - 1 ¼ NPT female
Material: brass, st. st.
Max. pressure: 10 bar
Max. temperature: 100 °C
Accuracy: ± 5% FS

 Variable Area Flowmeter/-switch DSV-3

Measuring -/switching range: 0,25 - 1,25 L/min ...
10 - 130 l /min water
Connection:G ¼ - G 1 ¼ , ¼ - 1 ¼ NPT female
Material: brass, st. st.
Max. pressure: 10 bar
Max. temperature: 100 °C
Accuracy: ± 5% FS
2 reed contacts

 

Variable Area Flowmeter/-switch - Low volume KDS

Measuring range: 0,1 - 1 L/h ... 20 - 200 L/h water
5,0 - 50 NL/h ... 600 - 6000 NL/h air
Connection: ¼ NPT
Material: stainless steel
Max. pressure: 40 bar (64 bar),
on request up to 420 bar
Max. temperature: -40...+130 °C
Accuracy: ± 3 % FS
Option: contacts, pressure regulator

Variable Area Switch-Low Volume SWK-1

Meas.--switching range: 0,05-0,1...13-24/minwater
Connection: G ½ female
Material: brass, st. st.
Max. pressure: 250 bar
Max.temperature: 100°C
Accuracy: +/- 4 % FS
Reed contact

 

Variable Area Flowmeter-Low Volume SWK-2

Meas.--switching range: 0,05-0,1...13-24/minwater
Connection: G ½ female
Material: brass, st. st.
Max. pressure: 250 bar
Max.temperature: 100°C
Accuracy: +/- 4 % FS
Reed contact, pointer indicator

Variable Area Flowswitch-Low Volume SWK-13

Meas.--switching range: 0,2-0,8...13-24/min water
Connection: G ½ female
Material: PVC
Max. pressure: 6 bar
Max.temperature: 60 °C
Accuracy: +/- 4 % FS
Reed contact

 

Variabile areaa flowmeter/switch BGK

Measuring range: 0,1 - 1 L/h ... 20 - 200 L/h water
5,0 - 50 NL/h ... 600 - 6000 NL/h air
Connection: flange DN10 - 25 or ANSI 1/2'', 3/4'', 1''
Material: stainless steel
Max. pressure: 40 bar (higher on request)
Max. temperature: -40...+130 °C
Accuracy: ± 3 % FS
Option: contact, analog output

Variable Area Flowmeter-All Metal BGN

Measuring -/switching range:
0,5 - 5 ..13.000 -130.000 L/h water
0,015 - 0,15 ...240 -2.400 Nm³ /h air
Connection: flange DN 15 ... DN 150, ANSI 3/4 ... 6
Material: st. st. 1.4404, PTFE-lining, Hastelloy
Max. pressure: PN 40 (16) bar
Max. temperature: 350°C
Accuracy :±1,6% of m. value (±2% of m. value for gases)
Options: contacts, analogue output, totalizer,
Hart, Profibus PA, ATEX

Variable Area Flowmeter-All Metal BGN-High Pressure

Measuring -/switching range:
0,5 - 5 ..13.000 -130.000 L/h water
0,015 - 0,15 ...240 -2.400 Nm³ /h air
Connection: flange DN 15 ... DN 150, ANSI 3/4 ... 6
Material: st. st. 1.4404, PTFE-lining, Hastelloy
Max. pressure: 600 bar
Max. temperature: 350°C
Accuracy :±1,6% of m. value (±2% of m. value for gases)
Options: contacts, analogue output, totalizer,
Hart, Profibus PA, ATEX

 Displacer Flowmeter/-switch-All Metall-Mounting Position Independent BGF

for horizontal mounting
Measuring -/switching range:
10 - 100 ... 4.000 - 40.000 L/h water
0,3 - 3,0 ...110 -1100 Nm³ /h air;
Connection: flange DN 15 ... DN 100, ANSI 3/4 ...4
Material: st. st. 1.4404, option PTFE-lining
Max. pressure: PN 40 (16) bar, on request max PN 600 bar
Max. temperature: -40...+200 °C (-40...+350°C on request)
Accuracy : ± 2 % of meas. value
Options: contacts, analogue output, totalizer,
Hart, Profibus PA, ATEX

 Variable Area Flow Switch-All Metal DSS

Switching range: 0,05 - 1 L/min ...10 -110 L/min water
Connection: G ¼...G 1 ¼ female
Material: brass, st. st.
Max. pressure: 250 bar (brass), 350 bar (st. st.)
Max. temperature: 100 °C
Accuracy: ± 5% FS

Variable Area-Flowmeter/-switch-All Metal SMV

Measuring -/switching range:0,05-1 L/min...10-250 L/min
water
Connection: G ¼... G11/4 female
Material: brass; st. st.
Max. pressure: 250 bar (brass); 350 bar (st. st.)
Max. temperature: 100 °C
Accuracy: ± 5 % FS
Option: reed contact

Displacer Flowmeters/-switch-All Metall SMO

Flow downward
Switching range:0,2-3...10-120 L/min water
Connection: G ¼..G 1 female
Material: brass, st. st.
Max. pressure: 250 bar (brass), 350 bar (st. st.)
Max. temperature: 100 °C
Accuracy: ± 5 % FS
Reed contact

Displacer Flowmeters/-switch-All Metall SMW

Flow horizontal
Switching range:0,2-3...10-120 L/min water
Connection: G ¼..G 1 female
Material: brass, st. st.
Max. pressure: 250 bar (brass), 350 bar (st. st.)
Max. temperature: 100 °C
Accuracy: ± 5 % FS
Reed contact

Displacer Flow Switch-All Metal SMN

Switching range: 1 - 100 L/min water
Switch point at approx .1 L/min falling
Connection: G1 female
Material: brass or st. st.
Max. pressure: 250 bar (brass), 350 bar (st. st.)
Max. temperature: 120 °C
Accuracy: ± 5 % FS
Reed contact

Viscosity Compensated Flowmeter/-switch-Plastic VKP

Meas. -/switching range: 2 - 20 ... 20 - 100 L/min water
1-18...10-75 L/min oil
Conn.: G 1 male, sold. pipe, con. parts G 1/2, G 3/4
Material: polysulfone
Max. pressure: 16 bar
Max. temperature: 120 °C
Accuracy: ± 5 % FS
Option: reed contact

Viscosity Compensated Flowmeter/-switch VKG

Measuring -/switching range: 0,1 - 0,45 ... 5 - 80 l /min
Connection: G ¼ ... G 1 female
Material: brass, st. st.
Max. pressure: 10 bar
Max. temperature: 100 °C
Accuracy: ± 5% FS
Options: reed contact, pointer indicator, analogue output

 Viscosity Compensated Flowmeter/-switch-All Metal VKM

Measuring -/switching range:0,01- 0,07 L/min..8 - 80
L/min
Connection: G ¼...G 1, ¼...1 NPT female
Material: brass, st. st.
Max. pressure: 250 (brass); 350 bar (st. st.)
Max. temperature: 100 °C
Accuracy: ± 4% FS
Options: reed contact, pointer indicator

Viscosity Compensated Flow Meter/-switch-All Metal VKM with ADI

Measuring -/switching range:0,01 - 0,063 L/min ... 8 - 72 L/min
L/min
Connection: G ¼...G 1, ¼...1 NPT female
Material: brass, st. st.
Max. pressure: 250 (brass); 350 bar (st. st.)
Max. temperature: 100 °C
Accuracy: ± 4% FS
Options: analogue output, digital display

Manifold Valves for Multiple Installation BVB

Max. flow: 24 L/min per group
Connection: G ½ female
Material: aluminum
Max. pressure: PN 64
Max. temperature: 100 °C
Max. 8 fold

Paddle Switch PSR

Switching range: 2,3-4,7 L/min...47,6-67,2 L/min water
Connection: G ¼... G 1 ½, ¼...1 ½ NPT
Material: brass, st. st.
Max. pressure: 100 bar
Max. temperature: 110 °C
Reed contact

Paddle Switch PSE

Switching range: 68-90 L/min...383-533 L/min L/min water
Connection: G ½, ½ NPT
Material: brass, st. st.
Max. pressure: 100 bar
Max. temperature: 110 °C
Reed contact

Paddle Switch-Polysulfone PPS

Switching range: 36...108 L/min water (rising)
18...72 L/min water (falling)
Connection: G 1, 1 NPT for DN 32 ...DN 80
Material: polysulfone
Max. pressure: 10 bar
Max. temperature: 105 °C
Adjustable accuracy: ± 20 % FS

Paddle Switch-Air LPS-P

Switching range: off: 1 m/s...8 m/s air
on: 2,5 m/s... 9,2 m/s air
Connection: square flange
Material: brass
Max. pressure: pressureless
Max. temperature: 85 °C

Paddle Bellow Flowswitch FPS

Switching range: off: 0,2-1 m³/h....73-166 m³/h water
on: 0,6-1,1m³/h ...85,1-173 m³/h water
Connection: G 1 male for DN 25...200, or G ½ and G3/4
Material: brass; st. st.
Max. pressure: 11 bar (brass); 30 bar (st. st.)
Max. temperature: 120 °C

Paddle Bellows Flowmeter and Monitor DPU

Measuring range: 3 - 55 l / min ... 50 - 600 l / min water
Connection: R ½ ... R 2, ½ ... 2 "NPT, flange DN15 ... DN50, ASME ½ ... 2",
Material: brass, stainless steel
Max. pressure: PN16
Max. temperature: 100 ° C
Accuracy: ± 3 ... ± 5% of full scale

Paddle Torsion Meter/Switch DPT-..C3

Measuring range: 5-30 L/min ... 850-1900 L/min water
Connection: G 3/8...G 3, 3/8 NPT...3 NPT,
Material: aluminum/bronze, st. st.
Max. pressure: PN 40
Max. temperature: 80 °C
Accuracy: ± 3 % FS

Paddle Torsion Meter/Switch DPT-..K

Measuring range: 5-30 L/min ... 850-1900 L/min water
Connection: G 3/8...G 3, 3/8 NPT...3 NPT,
Material: aluminum/bronze, st. st.
Max. pressure: PN 40
Max. temperature: 80 °C
Accuracy: ± 3 % FS

Buffle Flap Flow Flowmeter/-switch DWD

Measuring range: 1-10 L/min ... 360-3600 m³/h water
Connection: G 3/8...G 2, 3/8 NPT..2 NPT,
flange DN 10..DN 50, weld on flange. up to
NW 500
Material: brass, st. st., PVC
Max. pressure: PN 25
Max. temperature: 120 °C
Accuracy: ± 1,5 % FS

Flap Flowmeter/-switch TSK

Measuring range: 1,5-10....200-1.500 m³/h. water
Connection: wafer DN 50...DN 500
Material: steel, st. st., Polypropylene, PTFE, Hastelloy
Max. PN 40, PN16 (DN100-200), PN10 (from DN250)
Max. temperature: -40..+200 °C (-40...+300°C on request)
Accuracy: ± 2 % (1,0% ) FS
Options: contact, 4-20 mA, ATEX,
Hart-Protokoll, Profibus PA

Flow, Humidity and Temperature Hand-Held Measuring Unit HND-F115

For weight moisture or relative humidity
Measuring range: 0(4) -100 % rel. humidity
Accuracy: ± 0,1 / 0,2 % of rel.humidity
Supply: 9 V battery
Holding Function, min/max. -memory, alarm,
data logger, output 0-1 V, RS 232
Option: temperature-, flow measuring

Turbine Wheel-Pulse Output DRS-..F5

Measuring range: 2,0-40 L/min water
Connection: G ½, G 3/4, ¾ NPT
Material: Noryl, Ultem, brass, st.st.
Max. pressure: 16 bar, 200 bar (brass, st.st.)
Max. temperature: 80 °C
Accuracy: ± 1,5 % FS
Pulse output

Turbine Wheel-Analogue Output DRS-..L3

Measuring range: 2,0-40 L/min water
Connection: G ½, G 3/4, ¾ NPT
Material: Noryl, Ultem, brass, st.st.
Max. pressure: 16 bar, 200 bar (brass, st.st.)
Max. temperature: 80 °C
Accuracy: ± 1,5 % FS
Analogue output

Turbine Wheel-Analogue Output DRS-..L4 with AUF

Measuring range: 2,0-40 L/min water
Connection: G ½, G 3/4, ¾ NPT
Material: Noryl, Ultem, brass, st.st.
Max. pressure: 16 bar, 200 bar (brass, st.st.)
Max. temperature: 80 °C
Accuracy: ± 1,5 % FS
Analogue output, digital indicator

Turbine Wheel-Pointer Indicator DRH-..Z3

Measuring range: 2,0-40 L/min water
Connection: G ½, G 3/4, ¾ NPT
Material: Noryl, Ultem, brass, st.st.
Max. pressure: 16 bar, 200 bar (brass, st.st.)
Max. temperature: 80 °C
Accuracy: ± 1,5 % FS
Analogue output, pointer indicator

Turbine Wheel-Counter DRS with ZED

Measuring range: 2,0-40 L/min water
Connection: G ½, G 3/4, ¾ NPT
Material: Noryl, Ultem, brass, st.st.
Max. pressure: 16 bar, 200 bar (brass, st.st.)
Max. temperature: 80 °C
Accuracy: ± 1,5 % FS
Analogue output, totalizer, contacts, digital indicator

Turbine Wheel-Pulse Output TUR-1

Measuring range: 0,2-5 L/min ...2,5-100 m³/h water
Connection: flange DN 25..DN 100
Material: PVC, PVDF
Max. pressure: PN 10
Max. temperature: 60°C (PVC), 70 °C (PVDF)
Accuracy: ± 1 % FS
Pulse output

Turbine Wheel-Analogue Output TUR-2..M

Measuring range: 0,2-5 L/min ...2,5-100 m³/h water
Connection: flange DN 25..DN 100
Material: PVC, PVDF
Max. pressure: PN 10
Max. temperature: 60°C (PVC), 70 °C (PVDF)
Accuracy: ± 1 % FS
Analogue output

Turbine Wheel-Compact Electronic TUR-2..C3

Measuring range: 0,2-5 L/min ...2,5-100 m³/h water
Connection: flange DN 25..DN 100
Material: PVC, PVDF
Max. pressure: PN 10
Max. temperature: 60°C (PVC), 70 °C (PVDF)
Accuracy: ± 1 % FS
Analogue output, Contacts NPN/PNP, digital indicator

Turbine Wheel-Digital Display TUR-2..K

Measuring range: 0,2-5 L/min ...2,5-100 m³/h water
Connection: flange DN 25..DN 100
Material: PVC, PVDF
Max. pressure: PN 10
Max. temperature: 60°C (PVC), 70 °C (PVDF)
Accuracy: ± 1 % FS
Analogue output, pulse output,
contacts, digital indicator

Turbine Wheel-Pulse-Analogue Output DPE-..F, DPE-..L

Measuring range: 7-30 L/min ...100-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 2,5 % FS
Pulse output, analogue output

Turbine Wheel-Analogue Output DPE with AUF

Measuring range: 7-30 L/min ...100-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 2,5 % FS
Analogue output, digital indicator

Turbine Wheel-Compact Electronic DPE-..C3

Measuring range: 7-30 L/min ...100-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 2,5 % FS
Analogue output, Contacts NPN/PNP, digital indicator

Turbine Wheel-Pointer Indicator DPE-..Z3

Measuring range: 7-30 L/min ...100-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 2,5 % FS
Analogue output, pointer indicator

Turbine Wheel-Digital Display DPE with ADI

Measuring range: 7-30 L/min ...100-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 2,5 % FS
Analogue output, pulse output,
contacts, digital indicator

Turbine Wheel-Dosing Electronic DPE with ZED

Measuring range: 7-30 L/min ...100-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 2,5 % FS
Analogue output, totalizer, contacts, digital indicator

Turbine Wheel-Pulse-Analogue Output DRB-..F, DRB-..L

Measuring range: 5-30 L/min ...50-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Pulse output, analogue output

Analogue Output DRB with AUF

Measuring range: 5-30 L/min ...50-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Analogue output, digital indicator

Turbine Wheel-Pointer Indicator DRB-..Z3

Measuring range: 5-30 L/min ...50-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Analogue output, pointer indicator

Turbine Wheel-Digital Display DRB with ADI

Measuring range: 5-30 L/min ...50-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Analogue output, pulse output,
contacts, digital indicator

Turbine Wheel-Dosing Electronic DRB with ZED

Measuring range: 5-30 L/min ...50-750 L/min water
Connection: G ½... G 3, ½ NPT...3 NPT
Material: aluminum/bronze, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Analogue output, totalizer, contacts, digital indicator

Turbine Wheel Flowmeter TUV

Measuring range: 0,3-1,5 L/min ...35-400 L/minwater
Connection: G ¼...G 1 ½ female
Material: st. st.
Max. pressure: 100/400/640 bar
Max. temperature: 120 (350) °C
Linearity: ± 1% of m. value
Viscosity range: 1-30 m²/s
Pulse output

Low Volume Turbine Wheel Flowmeter SFL

Measuring range: 0,5-20 L/min water
Connection: G 3/8
Material: PVDF, st. st.
Max. pressure: 250 bar
Max. temperature: 90 °C
Accuracy: ±1% of m. value
Pulse output

Turbine Wheel Flowmeter-Counter Electronics DOT

Measuring range: 0,11-1,1 ... 700-7000 m³/h water
Connection: G ½...2, ½...2 NPT, flange DN 5...500
Material: st. st.
Max. pressure: 250 bar
Max. temperature: 120 °C
Linearity: ±0,5% of m. value

Turbine Wheel Flowmeter/-counter - Battery powered EDM

Without power supply (lithium battery)
Measuring range: 4-40 L/min ...80-800 L/min water
Connection: G ½...G2
Material: nylon, brass, st. st.
Max. pressure: 10/20/100 bar
Max. temperature: 60 °C
Accuracy: ± 1,5 % FS

Turbine Wheel-Low Volume PEL-L

Measuring range: 0,006-0,1 L/min ...0,1-28 L/min water
Connection: R ¼, R ½, hose connector
Material: GN, PVC, PFA, st. st., titan
Max. pressure: 5..345 bar
Max. temperature: 70 °C (135 °C)
Accuracy: ± 1,25 % FS
Pulse output

Rotating Vane-Low Volume-Pulse Output DPM-..F5

Measuring range: 0,015-0,7 L/min ...0,05-5 L/min water
connection: G 1/8, G ¼, 1/8 NPT, ¼ NPT
Material: brass nickle plated, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 1 (2,5) % FS
Pulse output

Rotating Vane-Low Volume-Analogue Output DPM-..L3

Measuring range: 0,015-0,7 L/min ...0,05-5 L/min water
connection: G 1/8, G ¼, 1/8 NPT, ¼ NPT
Material: brass nickle plated, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 1 (2,5) % FS
Analogue output

Rotating Vane-Low Volume-Analogue Output DPM-..L4 with AUF

Measuring range: 0,015-0,7 L/min ...0,05-5 L/min water
connection: G 1/8, G ¼, 1/8 NPT, ¼ NPT
Material: brass nickle plated, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 1 (2,5) % FS
Analogue output, digital indicator

Rotating Vane-Low Volume-Pointer Indicator DPM-..Z3

Measuring range: 0,015-0,7 L/min ...0,05-5 L/min water
connection: G 1/8, G ¼, 1/8 NPT, ¼ NPT
Material: brass nickle plated, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 1 (2,5) % FS
Analogue output,
pointer indicator

Rotating Vane-Low Volume-Compact Electronic DPM-..C3

Measuring range: 0,015-0,7 L/min ...0,05-5 L/min water
connection: G 1/8, G ¼, 1/8 NPT, ¼ NPT
Material: brass nickle plated, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 1 (2,5) % FS
Analogue output, Contacts NPN/PNP, digital indicator

Rotating Vane-Low Volume-Counter DPM with ZED

Measuring range: 0,015-0,7 L/min ...0,05-5 L/min water
connection: G 1/8, G ¼, 1/8 NPT, ¼ NPT
Material: brass nickle plated, st. st.
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 1 (2,5) % FS
Analogue output, totalizer, contacts, digital indicator

Rotating Vane-Low Volume-Analogue Output DPL-..L4 with AUF

Measuring range: 0,025-0,5 L/min ...1-25 L/min water
Connection: G ½ male or hose connector
Material: Polypropylene
Max. pressure: 10 bar
Max. temperature: 70 °C
Linearity: ± 1%
Analogue output, digital indicator

Rotating Vane-Low Volume-Compact Electronic DPL-..C3

Measuring range: 0,025-0,5 L/min ...1-25 L/min water
Connection: G ½ male or hose connector
Material: Polypropylene
Max. pressure: 10 bar
Max. temperature: 70 °C
Linearity: ± 1%
Analogue output, Contacts NPN/PNP, digital indicator

Rotating Vane-Low Volume-Pointer Indicator DPL-..Z3

Measuring range: 0,025-0,5 L/min ...1-25 L/min water
Connection: G ½ male or hose connector
Material: Polypropylene
Max. pressure: 10 bar
Max. temperature: 70 °C
Linearity: ± 1%
Analogue output,
pointer indicator

Rotating Vane-Low Volume-Counter DPL with ZED

Measuring range: 0,025-0,5 L/min ...1-25 L/min water
Connection: G ½ male or hose connector
Material: Polypropylene
Max. pressure: 10 bar
Max. temperature: 70 °C
Linearity: ± 1%
Analogue output, totalizer, contacts, digital indicator

Rotating Vane Flowmeter DPM

Measuring range: 3-55 L/min ...50-600 L/min water
Connection: R 1/2...R2, 1/2....2''NPT, flange DN15...DN50, ASME 1/2..2''
Material: brass, stainless steel
Max. pressure: PN16
Max. temperature: 100 °C
Accuracy: ± 1%

Rotating Vane-Low Volume KFF-1, KFG-1

Measuring range: 15-100 mL/min ...1-10 L/min water
25-100 mL/min ...100-500 L/min air
Connection: G 1/8...G ½
Material: ryton, brass, PTFE
Max. pressure: 35 bar
Max. temperature: 50 °C
Accuracy: ± 3% FS
Viscosity range: low viscosity
Pulse output, 0-5 VDC

Rotating Vane-Low Volume KFF-3, KFG-3

Measuring range: 15-100 mL/min ...1-10 L/min water
25-100 mL/min ...100-500 L/min air
Connection: G 1/8...G ½
Material: ryton, brass, PTFE
Max. pressure: 35 bar
Max. temperature: 50 °C
Accuracy: ± 3% FS
Viscosity range: low viscosity
0-5 VDC, digital display

Rotating Vane-Low Volume-Pulse Output DF-H

Measuring range: 0,08-0,5 L/min ...40-160 L/min water
Connection: G 1/8...G 1 1/2, flange DN 15..DN 50,
Material: brass, st. st., trogamide, polysulfone, PVDF
Max. pressure: 6/10/16/100 bar
Max. temperature: 80 °C
Accuracy: ± 2,5% FS
Pulse output

Rotating Vane-Low Volume-Analogue Output DF-MA

Measuring -/switching range: 0,08-0,5 L/min ...40-160 L/min water
Connection: G 1/8...G 1 1/2, flange DN 15..DN 50,
Material: brass, st. st., trogamide, polysulfone, PVDF
Max. pressure: 6/10/16/100 bar
Max. temperature: 80 °C
Accuracy: ± 2,5% FS
Analogue output

Rotating Vane-Low Volume-Counter DF-Z

Measuring -/switching range: 0,08-0,5 L/min ...40-160 L/min water
Connection: G 1/8...G 1 1/2, flange DN 15..DN 50,
Material: brass, st. st., trogamide, polysulfone, PVDF
Max. pressure: 6/10/16/100 bar
Max. temperature: 80 °C
Accuracy: ± 2,5% FS
Relays, analogue output, counter, digital display

Rotating Vane-Low Volume-Dosing Electronic DF-D

Measuring -/switching range: 0,08-0,5 L/min ...40-160 L/min water
Connection: G 1/8...G 1 1/2, flange DN 15..DN 50,
Material: brass, st. st., trogamide, polysulfone, PVDF
Max. pressure: 6/10/16/100 bar
Max. temperature: 80 °C
Accuracy: ± 2,5% FS
Relays, analogue output, batcher, digital display

Rotating Vane-Pulse Output DFT-11

Measuring -/switching range: 0,2-2 L/min ...3-60 L/min water
Connection: G ¼...G ¾, ¼ NPT... ¾ NPT
Material: brass
Max. pressure: 16 bar
Max. temperature: 80 °C
Accuracy: ± 2,5 (5) % FS
Pulse output

Rotating Vane-Pulse Output DFT-13

Measuring -/switching range: 0,2-2 L/min ...3-60 L/min water
Connection: G ¼...G ¾, ¼ NPT... ¾ NPT
Material: PTFE
Max. pressure: 5 bar
Max. temperature: 80 °C
Accuracy: ± 2,5 (5) % FS
Pulse output

Rotating Vane-Pulse Output DFT-13..E/G

Measuring -/switching range: 0,2-2 L/min ...3-60 L/min water
Connection: G ¼...G ¾, ¼ NPT... ¾ NPT
Material: brass, PTFE
Max. pressure: 16/6 bar
Max. temperature: 80 °C
Accuracy: ± 2,5 (5) % FS
Relays, analogue output, batcher, digital display, counter

Rotating Vane-Pulse-Analogue Output DRH-..F, DRH-..L

Measuring range: 0,2-0,8 L/min ...2,5-50 L/min water
Connection: G 3/8, G 1, 3/8 NPT, 1 NPT
Material: brass, st. st., POM, PVDF
Max. pressure: 100 bar
Max. temperature: 100 °C
Accuracy: ± 2,5 % FS
Pulse output, analogue output

Rotating Vane-Analogue Output DRH with AUF

Measuring range: 0,2-8 L/min ...2,5-50 L/min water
Connection: G 3/8, G 1, 3/8 NPT, 1 NPT
Material: brass, st. st., POM, PVDF
Max. pressure: 100 bar
Max. temperature: 100 °C
Accuracy: ± 2,5 % FS
Analogue output, digital indicator

Rotating Vane-Compact Electronic DRH-..C3

Measuring range: 0,2-8 L/min ...2,5-50 L/min water
Connection: G 3/8, G 1, 3/8 NPT, 1 NPT
Material: brass, st. st., POM, PVDF
Max. pressure: 100 bar
Max. temperature: 100 °C
Accuracy: ± 2,5 % FS
Analogue output, Contacts NPN/PNP, digital indicator

Rotating Vane-Digital Display DRH with ADI

Measuring range: 0,2-8 L/min ...2,5-50 L/min water
Connection: G 3/8, G 1, 3/8 NPT, 1 NPT
Material: brass, st. st., POM, PVDF
Max. pressure: 100 bar
Max. temperature: 100 °C
Accuracy: ± 2,5 % FS
Pulse output, analogue output,
Contacts, digital indicator

Rotating Vane-Counter DRH with ZED

Measuring range: 0,2-8 L/min ...2,5-50 L/min water
Connection: G 3/8, G 1, 3/8 NPT, 1 NPT
Material: brass, st. st., POM, PVDF
Max. pressure: 100 bar
Max. temperature: 100 °C
Accuracy: ± 2,5 % FS
Analogue output, totalizer, contacts, digital indicator

Rotating Vane-Pulse-Analogue Output DRG-..F, DRG-..L

Measuring range: 0,5-12 L/min ...10-140 L/min water
Connection: G 1/8... G 1, 1/8 NPT.. 1 NPT
Material: aluminum-bronze, st. st., Polypropylen
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Pulse output, analogue output

Rotating Vane-Analogue Output DRG with AUF

Measuring range: 0,5-12 L/min ...10-140 L/min water
Connection: G 1/8... G 1, 1/8 NPT.. 1 NPT
Material: aluminum-bronze, st. st., Polypropylen
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Analogue output,
digital indicator

Rotating Vane-Compact Electronic DRG-..C3

Measuring range: 0,5-12 L/min ...10-140 L/min water
Connection: G 1/8... G 1, 1/8 NPT.. 1 NPT
Material: aluminum-bronze, st. st., Polypropylen
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Analogue output, Contacts NPN/PNP, digital indicator

Rotating Vane-Pointer Indicator DRG-..Z3

Measuring range: 0,5-12 L/min ...10-140 L/min water
Connection: G 1/8... G 1, 1/8 NPT.. 1 NPT
Material: aluminum-bronze, st. st., Polypropylen
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Analogue output, pointer indicato

Rotating Vane-Digital Display DRG with ADI

Measuring range: 0,5-12 L/min ...10-140 L/min water
Connection: G 1/8... G 1, 1/8 NPT.. 1 NPT
Material: aluminum-bronze, st. st., Polypropylen
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Pulse output, analogue output,
Contacts, digital indicator

Rotating Vane-Dosing Electronic DRG with ZED

Measuring range: 0,5-12 L/min ...10-140 L/min water
Connection: G 1/8... G 1, 1/8 NPT.. 1 NPT
Material: aluminum-bronze, st. st., Polypropylen
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 3 % FS
Relays, analogue output, batcher, digital display

Rotating Vane-Flowmeter-Low Volume DTK

Measuring range: 0,05-0,6 ...1,0-12 L/min water
Connection: G 1/4, ¼ NPT
Material: st.steel
Max. pressure: 30 bar
Max. temperature: 80 (140) °C
Accuracy: ± 2 % FS

Rotating Vane Flowmeter-Insertion Version DOR

Measuring range: 0,36-6300 L/s water
Connection: G 1½, G 2, 1½ NPT, 2 NPT male
Material: st. st.
Max. pressure: 80 bar
Max. temperature: 200 °C
Linearity: ±1,5%

Dual-Ring Piston-Pendulum-Flowmeter-Low Volume LFM

Measuring range: 0,005-0,25 L/min water
Connection: G 1/8 female and swagelock 6mm
Material: st. st.
Max. pressure: 100 bar
Max. temperature: 70 °C
Accuracy: ± 2,5% of m. value
Pulse output

Rotating Vane Flowmeter DRH

Measuring range: 0.02-8...2.5-50 L/min water
Connection: G 3/8, G1, 3/8'' NPT, 1''NPT
Material: brass, stainless steel, POM, PVDF
Max. pressure: 100 bar
Max. temperature: 100 °C
Accuracy: ± 2.5%

Ring Piston Counter-Pulse Output DRZ-..F

Measuring -/switching range: 6-420 L/h oil
Connection: G1/8, G ¼, 1/8 NPT, ¼ NPT
Material: brass
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 1 % meas. value.
Pulse output

Ring Piston Counter-Analogue Output DRZ with AUF

Measuring -/switching range: 6-420 L/h oil
Connection: G1/8, G ¼, 1/8 NPT, ¼ NPT
Material: brass
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 1 % meas. value.
Analogue output, digital display

Ring Piston Counter-Compact Electronic DRZ-..C3

Measuring -/switching range: 6-420 L/h oil
Connection: G1/8, G ¼, 1/8 NPT, ¼ NPT
Material: brass
Max. pressure: 40 bar
Max. temperature: 80 °C
Accuracy: ± 1 % meas. value.
Analogue output, Contacts NPN/PNP, digital indicator

Oval Gear-Pulse Output OVZ-..I4

Measuring range: 0,1-2 L/min ...1,6-40 L/min liquid
Connection: G ¼...G ¾ female
Material: POM, aluminum
Max. pressure: 10 (40) bar
Max. temperature: 80 °C
Accuracy: ± 2,5% of m. value
Viscosity range: 10-800 mm²/s
Pulse output

Oval Gear-Analogue Output OVZ-..L4 with AUF

Measuring range: 0,1-2 L/min ...1,6-40 L/min liquid
Connection: G ¼...G ¾ female
Material: POM, aluminum
Max. pressure: 10 (40) bar
Max. temperature: 80 °C
Accuracy: ± 2,5% of m. value
Viscosity range: 10-800 mm²/s
Analogue output, digital display

Oval Gear-Compact Electronic OVZ-..C3

Measuring range: 0,1-2 L/min ...1,6-40 L/min liquid
Connection: G ¼...G ¾ female
Material: POM, aluminum
Max. pressure: 10 (40) bar
Max. temperatu