Humidity

Humidity


Humidity/temperature Measuring Instrument AFH-G

Operating temperature: -30...+80 °C
umidity: 30..100 % RH
Probe: polymer fibre inside st. st. housing, 220 mm
Max. pressure: pressureless
Max. temperature: -20...60 °C (housing),
-40..+80 °C (sensor)
Accuracy of temperature: ±0, 5 °C
humidity: ± 2,5 % RH (<40% RH: ± 3,5 % RH)
Output: temperature: Pt100 or 4-20 mA
humidity: 100-138,5 Ohm or 4-20 mA


Humidity/temperature Measuring Instrument (capacitive) AFK-G

Operating range: temperature: -60...+200 °C
humidity: 0... 100 % RH
Max. pressure: 25 bar
Max. temperature: +200 °C
Accuracy of temperature: ±0,1 °C
humidity: ± 2 %RH
Output: 2 x 4-20 mA


Humidity/temperature Measuring Instrument (capacitive) AFK-G2

Operating range: temperature: -60...+200 °C
humidity: 0... 100 % RH
Max. pressure: 25 bar
Max. temperature: +200 °C
Accuracy of temperature: ±0,1 °C
humidity: ± 2 %RH
Output: 2 x 4-20 mA


Humidity Measuring Instrument with Indicator (capacitive) AFA-G

Operating range: 0 - 100 % RH
Max. pressure: pressureless
Max. temperature: 0...60 °C
Accuracy : ± 2 % RH (5...95 % RH)
output: 4-20 mA
Plug-on display: 3,5-digit LED
Option: limit switch


Humidity/Temperature Transmitter AFK-E

For Industrial applications
Operating range temperature: -40...+180 °C
humidity: 0... 100 % RH
Max. pressure: 15 bar
Max. temperature: -40...60 °C (housing),
-40...+180 °C (sensor)
Accuracy of temperature: ±0, 2 °C
humidity: ± 2 % RH (0..90% RH)
Output: 0-5 V, 0-10V, 4-20 mA
Dew-point temperature, Freezing point temperature, abs. humidity, specific enthalpy,
Water-vapuor partial pressure, mixing ratio


Room Hygrostat AFS-G2

Operating range: 35 - 100 % RH
Max. pressure: pressureless
Max. temperature: 0...60 °C
Accuracy: ± 3 % RH
Contact: 1 micro switch, adjustable


Humidity Annex Switch AFS-G3

Operating range: 50 - 100 % RH
Max. pressure: pressureless
Max. temperature: 0...60 °C
Accuracy: ± 3 %RH
Contact: 1 micro switch, adjustable from inside


Hygrostat AFS-G1

Operating range: 35 - 100 % RH
Probe: polymere fibres inside st. st. housing, 220 mm
Max. pressure: pressureless
Max. temperature: -30...60 °C
Accuracy: ± 3,5 % RH (<50%RH: ± 4 % RH)
Contact: 1 micro switch


Hand-Held Humidity Precision Measuring Unit HND-F

For weight moisture or relative humidity
Measuring range: 0 -100 % rel. humidity
Accuracy: ± 0,1 / 0,2 % of rel.humidity
Supply: 9 V battery
Holding Function, min/max. -memory, alarm,
data logger, output 0-1 V, RS 232
Option: temperature-, flow measuring