Temperature Switch TWR
Switch points: +30 ... +120 (in 5 or 10 °C steps) fixed Connection:G ¾ male, brass or st. st. Electrical connection: plug DIN 43 650 Switching Accuracy: 30..+90 °C ± 5 °C 100-120 °C ± 7 °C Hysteris: max. 20 °C
|
Thermal Reed Switches TRS
Switch points: +10 ... +120 (in 5 bzw. 10 °C Schritten) fixed Connection:G ¼...G 1 male, brass or st. st. Electrical connection: cable Switching Accuracy: ± 3 °C Hysteresis: < 7 °C
|
Temperature Switch-Digital TDD-1, -3, -5, -7
Switch points: -20 ... +125 °C, adjustable Connection:G ½, G¾ male, ½, ¾ NPT st. st. Indication: 3-digit LED Electrical connection: plug M12x1 or cable Supply: 24 VDC Contact: 1 or 2 semiconductors PNP/NPN N/O or N/C adjustable Switching Accuracy: ±0, 5 °C (-10...+85 °C)
|
Glass Thermometer for Machines TGL
Measuring range: -60 ... +40 up to 0 ... 200 °C Connection: G ½ or ½ NPT, brass Housing Material: aluminum Housing length: 110, 150 or 200 mm Accuracy class: 1,0
|
Glass Thermometer for Machines TGK
Measuring range: -60 ... +40 up to 0 ... 200 °C Connection: G ½ or ½ NPT, brass Housing Material: plastic Housing length: 110, 150 or 200 mm Accuracy class: 1,0
|
Bi-metal Thermometer TBI-S
Measuring range: -30 ... +50 up to 0 ... 250 °C Connection: back or bottom smooth, st. st., copper alloy, St 35 Housing Material: st. st. Diameter of housing: 63, 80, 100 mm Accuracy class: 1,0
|
Bi-metal Thermometer TBI-I
Measuring range: -30 ... +50 up to 0 ... 500 °C Connection: back or bottom G ½ AG, st. st. Housing Material: st. st. Diameter of housing: 63, 80, 100 mm Accuracy class: 1,0 Option: mark pointer, gliding pointer
|
Shaft Thermometers according to DIN 13190 TNS
Measuring range: -20 ... +40 up to 0 ... 600 °C Connection: back or bottom G ½... G1, ½ NPT...1 NPT Housing Material: aluminum or st. st. Diameter of housing: 63, 80, 100,160 or 250 mm Accuracy class: 1,0 or 1,6 Option: contacts, gliding pointer, oil filling, and so on
|
Safety Thermometers with Contacts TNS, TNF
Measuring range: -20 ... +40 up to 0 ... 600 °C Connection: back or bottom G ½... G1, ½ NPT...1 NPT, TriClamp, and so on Housing Material: aluminum, st. st., plastic, steel Diameter of housing: 63, 80, 100,160 or 250 mm Accuracy class: 1,0 or 1,6 Option: contacts, gliding pointer, oil filling
|
Sterm Thermometer for Diesel Engines TND
Measuring range: 0 ... +600 up to 0 ... 800 °C Connection: bottom, G ½, G ¾ Housing Material: steel or st. st. with silicone filling Diameter of housing: 63, 80, 100 mm Accuracy class: 1,6 (63, 80 mm), 1,0 (100 mm) Option: damping spring
|
Predection Pipes for Thermometer TSH
Connection: G ½...G 1, welded 18mm...28 mm Material: st. st. Max. pressure: 25 bar

|
Temperature Sensor TDA
Measuring range: -20 ... +120 °C Connection:G 1/2, G3/4 male, 1/2, ¾ NPT st. st. Material: st.st. Indication: 3-digit LED Electrical connection: plug M12x1 or cable Supply: 24 VDC analogue output 0(4)-20 mA, programmable, Semiconductor PNP/NPN, digital display Accuracy: ±0, 5 °C (for range -10...+85 °C)
|
Temperature Sensor TDA-D6
Measuring range: -50 ... +125 °C Sensor: st.st. Indication: 3-digit LED Electrical connection: plug M12x1 or cable Supply: 24 VDC analogue output 0(4)-20 mA, programmable, Semiconductor PNP/NPN, digital display Accuracy: ±0, 5 °C (for range -10...+85 °C)
|
Infrared Thermometer (fixed installation) TIR-FA
Measuring range: 0 ... 120 up to 100 ... 500 °C Housing Material: stainless steel Accuracy class: ± 1,5 % of m. value (min 2,5 °C) Supply voltage: 18-30 VDC output: thermic voltage Typ J or K, or 10 mV/°C
|
Infrared Thermometer (fixed installation) TIR-SN
Measuring range: -20 ... +300 up to 1100 ... 2500 °C Housing Material: st. st. Accuracy class: ± 1,5 % of m. value (min 2,5 °C) Supply voltage: 18-30 VDC output: 4-20 mA
|
Precision Hand-Held Thermometer HND-T120
Measuring range: -50 ... +1150 °C Probe: Thermo couples K Accuracy: 1 % Supply: 9 V battery
|
Precision Hand-Held Thermometer HND-T115, -T215
Measuring range: -220 ... +1370 °C, -50..+1750°C Probe: Thermo couples Accuracy: ± 0,03 % of m. value Supply: 9 V battery Holding Function, min/max. -memory, °C/°F data logger, RS 232
|
Digital Thermometer DTM
Measuring range: -30 ... +50 up to 0...400 °C Connection: back or bottom G ½... G1, 1/2 ... 1 NPT Housing Material: st. st., back polyamides diameter of housing: 100 mm Accuracy class: 0,5 Option: anlaogue output, up to 2(4) contacts, peak memory, RS 232
|
Temperature Sensor TSA
Measuring range: -40 ... 150 °C Connection: G ¼... G 1 Connection Material: brass or st. st. output: NTC or Pt 100
|
Resistance Thermometers for harsh operational conditions TNK
for diesel engines in railway or ship building Measuring range: -80 ... +150 °C Connection: G ½.. ½ NPT, M18x1,5 Predective tubes: brass, bronze (sea-water resistant), st. st. Sensor: Pt 100, Pt 1000, Ni 100, 2,3 or 4-wire Certificates: GL
|
Resistance Temperature Probe with Connection Box LTS-A
Pt100, class A acc. DIN IEC 751 Range: -50...+250 °C Connection: G 1/2, M12 for hygenic sleeve LZE Material: st.st. Max. pressure: 10 bar Option: head mounted transmitter 4-20 mA, fast responding sensor tip, longer neck for higher temperatures
|
Resistance Temperature Probe-Compact Version LTS-K
Pt100, class A acc. DIN IEC 751 Range: -50...+250 °C Connection: G 1/2, M12 for hygenic sleeve LZE Material: st.st. Max. pressure: 10 bar Option: head mounted transmitter 4-20 mA, fast responding sensor tip, longer neck for higher temperatures, KOBUS
|
Pipe Temperature Sensor for Reliable Dead-Zone-Free TWP
Measuring range:-20 ... +200 °C Connection: Hygenic connection, Triclamp Pipe: st. st. DN 15..DN 80 Sensor: Pt100 Head B or field housing
|
Insertion Resistance Thermometers TWE-1
Measuring range: -20 ... +200 up to .-20... +600 °C Connection: G ¼, G ½, M10x1 Bulb Material: st. st. Sensor: Pt 100, 2,3 or 4-wire, class B Cable: st.st. braided,silicone, head Form MA
|
Insertion Resistance Thermometers TWE-2
Measuring range: -20 ... +400 °C Connection: M10x1 Bulb Material: st. st. Sensor: Pt 100, 2,3 or 4-wire, class B Cable: st.st. Braided
|
Insertion Resistance Thermometers TWE-3
Measuring range: -20 ... +300 °C Connection: M8 Bulb Material: st. st. Sensor: Pt 100, 2,3 or 4-wire, class B Cable: st.st. Braided
|
Resistance Thermometers with Bayonet Lock TWE-5
Measuring range: -20... +350 °C Bulb Material: st. st. Sensor: Pt 100, 2,3 or 4--wire, class B Cable: st.st. Braided
|
Immersion/Insertion Resistance Thermometers TWE-6, -7, -8
Measuring range: -20... +350 °C Connection: bayonet with spring pressure Bulb Material: st. st. Sensor: Pt 100, 2,3 or 4--wire, class B Cable: st.st. Braided
|
Insertion Resistance Thermometers TWE-K
Measuring range: -20 ... +150 °C Connection: G ¼, G ½, G ¾, M12x1 Bulb Material: st. st. Sensor: Pt 100, 2-wire, class B Cable: silicone
|
Sheath Resistance Thermometers TWM
Measuring range: -20... +350 °C Connection: bayonet with spring pressure Bulb Material: st. st. Sensor: Pt 100, 2,3 or 4--wire, class B Cable: st.st. Braided
|
Resistance Thermometers TWL
Measuring range: -200...+750 °C Connection: thread, flange, weld-on sleeve Bulb Material: st. st. Sensor: Pt 100, 2,3 or 4-wire, class A or B Option: head mounted transmitter 4-20 mA, HART, Profibus, Fieldbus
|
Room Thermometers TWL-ST
Measuring range: -20...+60 °C Connection: wall mounting Sensor: Pt 100, class A or B, 4-20 mA
|
Contact Resistance Thermometers TWA
Measuring range: -20...+60 °C Connection: wall mounting Sensor: Pt 100, class A or B, 4-20 mA
|
Thermocouples (according to DIN) TTD
Predection tube Form AM, AK, B, BM, MA Measuring range: -200.. +600 up to -200... 1150 (1200) °C Connection: G ½, sliding flange Material of predective tubes: steel, st. st., ceramics Sensor: FeCu-Ni, NiCr-Ni, class 2 Option: head mounted transmitter 4-20 mA
|
Screw-in Thermocouples TTE-1
Measuring range: -200 ... +600 °C Connection: G ½, M10x1 Bulb Material: st. st. Sensor: FeCu-Ni, NiCR-Ni, class 2 Cable: st.st. braided
|
Thermocouples with Bayonet Lock TTE-5
Measuring range:0 ... +400 °C Connection: bayonet with spring pressure Bulb Material: st. st. Sensor: FeCu-Ni, NiCr-Ni, class 2 Cable:st.st. Braided
|
Immersion/Insertion Thermocouples TTE -6/-8
Measuring range: 0 ... +600 °C Bulb Material: st. st. Sensor: FeCu-Ni, NiCr-Ni, class 2 Cable: st.st. braided, PTFE
|
Thermocouples TTL
Measuring range: -200...+1600 °C Connection: thread, flange, weld-on sleeve Material of predective tubes: steel, st. st., ceramics Sensor: FeCu-Ni, NiCr-Ni, class 1 or 2 Option: head mounted transmitter 4-20 mA
|
Sheath Thermocouples TTM
Measuring range: -50 ... +1100 °C Bulb: st. st., inconel, D= 0,5...6,0 mm Sensor: FeCu-Ni, NiCr-Ni, class 2 Connection: cable made of silicone, flat connector, head Form MA Accessories: connections
|
Digital Panel Indicators DAG-A
Programmable, 4-digit LED,red Dimensions: 96x48, 96x24, 48x24, Input: temperature, current, voltage Min/max.-memory, Tara-function Options: LED blue, green, or orange
|
Digital Indicator and Controller DAG-S,-M
Programmable, 5-digit LED, red Dimensions: 96 x 48, 48 x 24, Input: temperature, frequency, current, voltage Output: 1 or 2 x 0(4) - 20 mA / 0 - 10 V, RS 232, RS 485 Min/Max-memory, zero-key for HOLD, TARA 30 parameter driven setpoints, volume measuring (totaliser) Options: sensor supply, 2(4) contacts, 8 PhotoMos, LED blue, green, orange or tricolor
|
Thermostats for industrial Applications TER
Switching range: -20 ... +20 ... +80... +130°C, adjustable Material: aluminium (housing) copper, brass or stainless steel (probe) Micro switch: SPDT max. 250 VAC, 8 (5) A at 250 VAC, 8 A at 24 VDC

|
Rod Thermostat TEA-S
Switching range: -30 ... +30 ... +50... +120°C, adjustable Connection: R ½ Material: plastic (housing) copper (probe) Micro switch: SPDT, 24 - 250 VAC, 15 A at 250 VAC, 8 A at 250 VAC inductive
|
Capillary Thermostat TEA-K
Switching range: -30 ... +30 ... +50... +120°C, adjustable Material: plastic (housing) copper (probe) Micro switch: SPDT, 24 - 250 VAC, 15 A at 250 VAC, 8 A at 250 VAC inductive Single or double contact
|
Room Thermostat TEA-R
Switching range: -30 ... +30 ... 0 ... +60°C, adjustable Material: plastic (housing) copper (probe) Micro switch: SPDT, 24 - 250 VAC, 15 A at 250 VAC, 8 A at 250 VAC inductive Single or double contact
|
Bi-metal Thermometer TBE
Measuring range: -50 ... +50 ... 0 ... +600°C Connection: back or bottom, G ½, G ¾, ½" NPT, ¾" NPT male thread, stainless steel Housing material: stainless steel Housing: Ø 100, 125, 150 mm Accuracy class: 1.0Kovinski termometer TBE
|
Thermowells TWL-0
Connection: G ½ ... G 1, ½ ... 1" NPT, flange DN15 ... 50, ASME ½ ... 2", weld-in ¾ ... 1¼" Material: stainless steel 1.4404 Max. length: 1000 mm (5000 mm) pmax: 250 bar
|
Digital Thermometer DTB
Measuring range: -50 ... 200°C Indication: 4-digit LCD, 6.35 mm Connection: G ¼, G ½ male thread, ¼" NPT, ½" NPT pmax: 500 psig (probe) Housing material: stainless steel 316 Housing: Ø 81 mm Accuracy: ±(0.2 + 0.002 x [T])°C Power supply: (2) 3.6 V batteries Protection: NEMA 4X / IP67
|
Digital Thermometer DTE
Measuring range: -200 ... 850°C Display: 6-digits LCD (alphanumeric), 15,8 mm Accuracy: ±(0,1% of reading + 0,2°C) for Pt100 Connection: G ¼, G ½ AG, ¼" NPT, ½" NPT (with compression fitting) pmax: 34 bar (probe) Material Housing: stainless steel Housing: Ø 113 mm Power Supply: 3,6 V Battery
|
Insertion Temperature Sensors with/ without Transmitter MMA
Measuring range: -198 ... +250°C Connection: thread, clamp DIN 32676, VARIVENT®, UNION NUT DIN 11851 Bulb Material: stainless steel Sensor: Pt 100 Electrical connection: plug DIN 43650, M12 Output: Pt100 or 4 - 20 mA Option: plug-on display model AUF
|
Temperture Transmitter KM
Measuring range: programmable HART® Input: Pt100 / 500 / 1000, Ni100 / 500 / 1000, thermocouples, resistance, mV Output: 4 - 20 mA Supply: 7.5 ... 45 VDC
|
Resistance Thermometers MWD
Measuring range: -198 ... +600°C Connection: thread, flange, weld-on sleeve Bulb material: stainless steel Sensor: Pt100, 2, 3 or 4-wire, class A, B, 1/3 or 1/10 DIN Option: head mounted transmitter 4 - 20 mA, HART®, Profibus® PA, Fliedbus®
|