VI series

VI series

Advantages

  • water saving: at suction pressures < 600 mbar, the water can be completely retained in the pump
  • low noise due to optimized hydraulics and separation
  • low calcification risk and easy temperature control possible
  • easy disassembly due to inverted design and O-ring sealing

Possible applications

  • extruder degasification
  • sterilization of surgical instruments, textiles and beds (steam and gas sterilization)


Performance data

Max. suction capacity Min. inlet pressure Possible media Sound pressure level Temperature of
operational liquid
Temperature of
absorbed gas
between 2.2 m³/h and 55 m³/h up to 33 mbar dry and humidified gases  65 - 68 db(A) at 80 mbar up to 80 °C up to 120 °C
Design Motor Materials Connections Shaft sealing
  • single-stage pumps in inverted design with valves and internal water restraining system
  • ATEX approval for the entire series:
    device group II, device category 2G,
    type of protection IIB, temperature class T4
0.12 - 2.2 kW / 0.16 - 3.0 HP
AC / three-phase motors
non-ferrous metal / stainless steel G 1/8 to G 1 mechanical seal

Data for 50 Hz

Type Speed
[rpm]
Suction
capacity

[m³/h]
Min. inlet
pressure

[mbar]
VI 2 2850 2.2 45
VI 8 2850 9.5 40
VI 18 2850 18 40
VI 25 2850 24 40
VI 30 2850 27 33
VI 55 2850 46 33

Data for 60 Hz

Type Speed
[rpm]
Suction
capacity

[m³/h]
Min. inlet
pressure

[mbar]
VI 2 3450 2.4 45
VI 8 3450 11.4 40
VI 18 3450 22 40
VI 25 3450 29 40
VI 30 3450 33 33
VI 55 3450 55 33